Home
›
ENGINE ยท 2AD-FHV
›
EMISSION CONTROL
›
DIFFERENTIAL PRESSURE SENSOR
DIFFERENTIAL PRESSURE SENSOR > INSTALLATION
for Preparation
Click here
1. INSTALL DIFFERENTIAL PRESSURE SENSOR ASSEMBLY
Connect the 2 vacuum hoses.
NOTICE:
Connect the vacuum hoses so that the painted marks of the 2 vacuum hoses are as shown in the illustration.
Install the sensor with the nut.
Torque:
6.5 N*m{ 66 kgf*cm , 58 in.*lbf }
Connect the sensor connector.