Home › ENGINE · 2AD-FHV › EMISSION CONTROL › EGR BYPASS VALVE SWITCHING VALVE

EGR BYPASS VALVE SWITCHING VALVE > INSPECTION

for Preparation Click here



1. INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY


    A201836E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    28.3 to 31.1 Ω

    Text in Illustration 
    *1
    Component without harness connected
    (No. 1 Vacuum Switching Valve)



    A114883E03
  1. Check VSV operation.

    1. Check that air does not flow from port A to port B.



    A114884E02
  1. Apply battery voltage across the terminals.

  1. Check that air flows from port A to port B.
    If the result is not as specified, replace the No. 1 vacuum switching valve assembly.