DTC P0110 Intake Air Temperature Circuit Malfunction |
DTC P0112 Intake Air Temperature Circuit Low Input |
DTC P0113 Intake Air Temperature Circuit High Input |

| DTC No. | Proceed to | DTC Detection Condition | Trouble Area |
| P0110 | Step 2 | Open or short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0112 | Step 6 | Short in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| P0113 | Step 4 | Open in Intake Air Temperature (IAT) sensor circuit for 0.5 seconds (1 trip detection logic) |
|
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 140°C (284°F) or higher | Short circuit |

| 1.CHECK DTC OUTPUT |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the intelligent tester on.
Select the following menu items: Powertrain / Engine and ECT / DTC.
Read the DTCs.
| Display (DTC output) | Proceed to |
| P0110 | A |
| P0112 | B |
| P0113 | C |
|
| ||||
|
| ||||
| A | |
| 2.READ VALUE USING INTAKE AIR TEMPERATURE SENSOR (INTAKE AIR) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the tester.
| Temperature Displayed | Proceed to |
| -40°C (-40°F) | A |
| 140°C (284°F) or higher | B |
| Same as actual IAT | C |
|
| ||||
|
| ||||
| A | |
| 3.CHECK MASS AIR FLOW METER (CHECK FOR OPEN IN SENSOR) |
![]() |
Confirm the good connection of the Mass Air Flow (MAF) meter.
Disconnect the MAF meter connector.
Connect the terminals THA and E2 of the MAF meter wire harness side connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the tester.
Reconnect the MAF meter connector.
|
| ||||
| NG | |
| 4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the MAF meter connector.
Disconnect the ECM connector.
Measure the resistance between the terminals.
| Tester Connection | Specified Condition |
| THA (B96-71) - THA (B1-1) | Below 1 Ω |
| ETHA (B96-74) - E2 (B1-2) | Below 1 Ω |
| Tester Connection | Specified Condition |
| THA (B96-71) or THA (B1-1) - Body ground | 10 kΩ or higher |
| ETHA (B96-74) or E2 (B1-2) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK MASS AIR FLOW METER (CHECK FOR SHORT IN SENSOR) |
![]() |
Disconnect the MAF meter connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Intake Air.
Read the value displayed on the tester.
Reconnect the MAF meter connector.
|
| ||||
| NG | |
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER- ECM) |
![]() |
Disconnect the MAF meter connector.
Disconnect the ECM connector.
Measure the resistance between the terminals.
| Tester Connection | Specified Condition |
| THA (B96-71) or THA (B1-1) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||