DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 | Heated Oxygen (HO2) sensor heater current less than 0.3 A (1 trip detection logic) |
|
| P0038 | Heated Oxygen (HO2) sensor heater current more than 2 A (1 trip detection logic) |
|
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
![]() |
Disconnect the B19 Heated Oxygen (HO2) sensor connector.
Measure the resistance of the HO2 sensor connector.
| Tester Connection | Specified Condition |
| HT1B (1) - +B (2) | 11 to 16 Ω at 20°C (68°F) |
| HT1B (1) - E2 (4) | 10 kΩ or higher |
Reconnect the HO2 sensor connector.
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (+B OF HO2 SENSOR) |
![]() |
Disconnect the B19 HO2 sensor connector.
Turn the ignition switch on (IG).
Measure the voltage between the terminals of the B19 HO2 sensor connector and body ground.
| Tester Connection | Specified Condition |
| +B (B19-2) - Body ground | 9 to 14 V |
Reconnect the HO2 sensor connector.
|
| ||||
| NG | |
| 3.INSPECT INTEGRATION RELAY (EFI MAIN RELAY) |
Remove the integration relay from the engine room relay block.
Inspect the EFI MAIN fuse.
![]() |
Remove the EFI MAIN fuse from the integration relay.
Measure the EFI MAIN fuse resistance.
Reinstall the EFI MAIN fuse.
Inspect the EFI MAIN relay.
Measure the EFI MAIN relay resistance.
| Tester Connection | Specified Condition |
| 1C-1 - 1A-4 | 10 kΩ or higher |
| Below 1 Ω (Apply battery voltage between terminals 1A-2 and 1A-3) |
Reinstall the integration relay.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (HO2 SENSOR - INTEGRATION RELAY) |
![]() |
Disconnect the B19 HO2 sensor connector.
Remove the integration relay from the engine room No. 1 relay block (R/B).
Measure the resistance.
| Tester Connection | Specified Condition |
| +B (B19-2) - Engine room No. 1 R/B (1A-4) | Below 1 Ω |
| Tester Connection | Specified Condition |
| +B (B19-2) or Engine room No. 1 R/B (1A-4) - Body ground | 10 kΩ or higher |
Reconnect the HO2 sensor connector.
Reinstall the integration relay.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (HO2 SENSOR - ECM) |
![]() |
Disconnect the B19 HO2 sensor connector.
Disconnect the B32 ECM connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| HT1B (B19-1) - HT1B (B32-47) | Below 1 Ω |
| Tester Connection | Specified Condition |
| HT1B (B19-1) or HT1B (B32-47) - Body ground | 10 kΩ or higher |
Reconnect the HO2 sensor connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 6.CHECK WHETHER DTC OUTPUT RECURS |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the tester ON.
Clear DTCs (Click here).
Start the engine.
Allow the engine to idle for 2 minutes or more.
Select the following menu items: Powertrain / Engine and ECT / DTC.
Read DTCs.
| Display (DTC Output) | Proceed to |
| No output | A |
| P0037 or P0038 | B |
|
| ||||
| A | ||
| ||