Home › ENGINE · 3ZR-FAE › EMISSION CONTROL › PURGE VALVE

PURGE VALVE > INSPECTION

for Preparation Click here



1. INSPECT PURGE VSV


    A211313E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    23 to 26 Ω
    1 - VSV body
    Always
    10 MΩ or higher
    2 - VSV body
    Always
    10 MΩ or higher



  1. Check the operation of the purge VSV.



      A211314E01
    1. Check that air does not flow from port E to port F.



    2. A211315E01
    3. Apply battery voltage across terminals 1 and 2.

    4. Check that air flows from port E to port F.
      If the result is not as specified, replace the purge VSV.