DTC P0230 Fuel Pump Primary Circuit |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0230 | Open or short in F/PMP relay circuit (1 trip detection logic) |
|

| 1.CHECK TERMINAL VOLTAGE (F/PMP RELAY POWER SOURCE) |
![]() |
Remove the F/PMP relay from the engine room No. 1 relay block.
Measure the voltage of the engine room No. 1 relay block terminal.
| Tester Connection | Condition | Specified Condition |
| F/PMP relay holder terminal (2) - Body ground | STA signal ON | 9 to 14 V |
| F/PMP relay holder terminal (2) - Body ground | STA signal OFF | 0 to 3 V |
|
| ||||
| OK | |
| 2.INSPECT RELAY (Marking: F/PMP) |
![]() |
Remove the F/PMP relay from the engine room No. 1 relay block.
Measure the resistance of the F/PMP relay.
| Tester Connection | Specified Condition |
| 3 - 4 | Below 1 Ω |
| 3 - 4 | 10 kΩ or higher (when battery voltage applied to terminals 1 and 2) |
| 3 - 5 | 10 kΩ or higher |
| 3 - 5 | Below 1 Ω (when battery voltage applied to terminals 1 and 2) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (F/PMP RELAY - ECM) |
![]() |
Remove the F/PMP relay from the engine room No. 1 relay block.
Disconnect the ECM connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| F/PMP relay holder terminal (1) - B96-59 (FPR) | Below 1 Ω |
| F/PMP relay holder terminal (1) or B96-59 (FPR) - Body Ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||