DTC P0100 Mass or Volume Air Flow Circuit |
DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100 | MAF meter voltage less than 0.2 V, or more than 4.9 V for 3 seconds (1 trip detection logic) |
|
| P0102 | MAF meter voltage less than 0.2 V for 3 seconds (1 trip detection logic) |
|
| P0103 | MAF meter voltage more than 4.9 V for 3 seconds (1 trip detection logic) |
|
| Mass Air Flow Rate (g/sec.) | Malfunction |
| Approximately 0.0 |
|
| 271.0 or more |
|

| 1.READ VALUE USING INTELLIGENT TESTER (MASS AIR FLOW RATE) |
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester ON.
Select the following menu items: Powertrain / Engine and ECT / Data List / MAF.
Read the values displayed on the tester.
| Mass Air Flow Rate (g/sec.) | Proceed to |
| 0.0 | A |
| 271.0 or more | B |
| Between 1.0 and 270.0 (*1) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the B1 Mass Air Flow (MAF) meter connector.
Turn the ignition switch on (IG).
Measure the voltage between the terminal of the wire harness side connector and body ground.
| Tester Connection | Specified Condition |
| +B (B1-3) - Body ground | 9 to 14 V |
Reconnect the MAF meter connector.
|
| ||||
| OK | |
| 3.INSPECT MASS AIR FLOW METER (VG VOLTAGE) |
![]() |
Output voltage inspection.
Disconnect the B1 MAF meter connector.
Apply battery voltage across terminals +B and E2G.
Connect the positive (+) tester probe to terminal VG, and negative (-) tester probe to terminal E2G.
Measure the voltage.
| Tester Connection | Specified Condition |
| VG (5) - E2G (4) | 0.2 to 4.9 V |
Reconnect the MAF meter connector.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the B1 MAF meter connector.
Disconnect the B32 ECM connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| VG (B1-5) - VG (B32-118) | Below 1 Ω |
| E2G (B1-4) - E2G (B32-116) |
| Tester Connection | Specified Condition |
| VG (B1-5) or VG (B32-118) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY) |
![]() |
Disconnect the B1 MAF meter connector.
Remove the integration relay from the engine room No. 1 relay block.
Measure the resistance.
| Tester Connection | Specified Condition |
| +B (B1-3) - 1A-4 | Below 1 Ω |
| Tester Connection | Specified Condition |
| +B (B1-3) or 1A-4 - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reinstall the integration relay.
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
![]() |
Disconnect the B1 MAF meter connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| E2G (B1-4) - Body ground | Below 1 Ω |
Reconnect the MAF meter connector.
|
| ||||
| NG | |
| 7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
![]() |
Disconnect the B1 MAF meter connector.
Disconnect the B32 ECM connector.
Measure the resistance.
| Tester Connection | Specified Condition |
| VG (B1-5) - VG (B32-118) | Below 1 Ω |
| E2G (B1-4) - E2G (B32-116) |
| Tester Connection | Specified Condition |
| VG (B1-5) or VG (B32-118) - Body ground | 10 kΩ or higher |
Reconnect the MAF meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||