Home › ENGINE · 2GR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM

DTC    P0100    Mass or Volume Air Flow Circuit

DTC    P0102    Mass or Volume Air Flow Circuit Low Input

DTC    P0103    Mass or Volume Air Flow Circuit High Input

for Preparation Click here


DESCRIPTION

The Mass Air Flow (MAF) meter is a sensor that measures the amount of air flowing through the valve.
The ECM uses this information to determine the fuel injection time and to prove appropriate air-fuel ratio.
Inside the MAF meter, there is a heated platinum wire which is exposed to the flow of intake air.
By applying a specific electrical current to the wire, the ECM heats it to a given temperature. The flow of incoming air cools both the wire and an internal thermistor, affecting their resistance. To maintain a constant current value, the ECM varies the voltage applied to these components in the MAF meter. The voltage level is proportional to the airflow through the sensor, and the ECM uses it to calculate the intake air volume.
The circuit is constructed so that the platinum hot wire and the temperature sensor provide a bridge circuit, and the power transistor is controlled so that the potentials of A and B remain equal to maintain the predetermined temperature.

HINT:
When any of these DTCs are set, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is calculated by the ECM, according to the engine RPM and throttle valve position. Fail-safe mode continues until a pass condition is detected.


A140749E04


DTC No.
DTC Detection Condition
Trouble Area
P0100
Open or short in Mass Air Flow (MAF) meter circuit for 3 seconds (1 trip detection logic)
  1. Open or short in mass air flow (MAF) meter circuit
  2. MAF meter
  3. ECM
P0102
Open in Mass Air Flow (MAF) meter circuit for 3 seconds (1 trip detection logic)
  1. Open in MAF meter circuit
  2. MAF meter
  3. ECM
P0103
Short in Mass Air Flow (MAF) meter circuit for 3 seconds (1 trip detection logic)
  1. Short in MAF meter circuit (+B circuit)
  2. MAF meter
  3. ECM

HINT:
When any of these DTCs are set, check the air-flow rate by entering the following menus on the intelligent tester: Powertrain / Engine and ECT / Data List / MAF.

Mass Air Flow Rate (gm/s)
Malfunction
Approximately 0.0
  1. Open in Mass Air Flow (MAF) meter power source circuit
  2. Open or short in VG circuit
271.0 or more
Open in ELG circuit


WIRING DIAGRAM


A136190E05


INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction (Click here).

1.READ VALUE USING MASS AIR FLOW METER (MAF)
  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.

  1. Read the values displayed on the tester.

    Result:

    Mass Air Flow Rate (gm/s)
    Proceed to
    0.0
    A
    271.0 or more
    B
    Between 1.0 and 270.0 (*1)
    C

    *1: The value must be changed when the throttle valve is open or closed.



B
Go to step 5

C
CHECK FOR INTERMITTENT PROBLEMS (Click here)
A


2.INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE)


    A127724E01
  1. Disconnect the mass air flow (MAF) meter connector.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Specified Condition
    +B (B1-3) - Body ground
    9 to 14 V

  1. Reconnect the MAF meter connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI NO. 1 FUSE - MASS AIR FLOW METER)
OK


3.INSPECT MASS AIR FLOW METER (VG VOLTAGE)


    A127786E12
  1. Inspect the output voltage.

    1. Apply battery voltage across terminals +B and E2G.

    2. Connect the positive (+) tester probe to terminal VG, and the negative (-) tester probe to terminal E2G.

    3. Measure the voltage between the terminals.

      Standard voltage:
      Tester Connection
      Specified Condition
      VG (B1-5) - E2G (B1-4)
      0.2 to 4.9 V



NG
REPLACE MASS AIR FLOW METER (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    A127959E67
  1. Disconnect the MAF meter connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance between the terminals.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    VG (B96-72) - VG (B1-5)
    Below 1 Ω
    E2G (B96-73) - E2G (B1-4)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    VG (B96-72) or VG (B1-5) - Body ground
    10 kΩ or higher
    E2G (B96-73) or E2G (B1-4) - Body ground
    10 kΩ or higher

  1. Reconnect the MAF meter connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

5.CHECK HARNESS AND CONNECTOR (SENSOR GROUND)


    A127724E03
  1. Disconnect the MAF meter connector.

  1. Measure the resistance between the terminals.

    Standard resistance:
    Tester Connection
    Specified Condition
    E2G (B1-4) - Body ground
    Below 1 Ω

  1. Reconnect the MAF meter connector.



OK
REPLACE MASS AIR FLOW METER (Click here)
NG


6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)


    A127959E67
  1. Disconnect the MAF meter connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance between the terminals.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    VG (B96-72) - VG (B1-5)
    Below 1 Ω
    E2G (B96-73) - E2G (B1-4)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    VG (B96-72) or VG (B1-5) - Body ground
    10 kΩ or higher
    E2G (B96-73) or E2G (B1-4) - Body ground
    10 kΩ or higher

  1. Reconnect the MAF meter connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)