DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P2716 | Condition (a) and (b) below is detected for 1 sec. or more (1 trip detection logic): (a) SLT - terminal: 0 V (b) SLT - terminal: 12 V |
|

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
![]() |
Disconnect the B29 wire connector.
Measure the resistance of the transmission wire.
| Tester Connection | Condition | Specified Condition |
| 2 (SLT+) - 7 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 2 (SLT+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| 7 (SLT-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
Connect the B29 wire connector.
![]() |
Disconnect the B32 ECM connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| B32-76 (SLT+) - B32-75 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| B32-76 (SLT+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| B32-75 (SLT-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove the shift solenoid valve SLT.
Measure the resistance of the solenoid valve.
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||