DTC P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0748 | Duty cycle to shift solenoid valve SL1 is 100% (1 trip detection logic) |
|

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1) |
![]() |
Disconnect the B29 wire connector.
Measure the resistance of the transmission wire.
| Tester Connection | Condition | Specified Condition |
| 5 (SL1+) - 10 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 5 (SL1+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| 10 (SL1-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
Connect the B29 wire connector.
![]() |
Disconnect the B32 ECM connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| B32-57 (SL1+) - B32-77 (SL1-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| B32-57 (SL1+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| B32-77 (SL1-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL1 |
![]() |
Remove the shift solenoid valve SL1.
Measure the resistance of the solenoid valve.
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||