HAZARD WARNING SWITCH > INSPECTION |
| 1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY |
![]() |
Measure the resistance of the switch.
| Tester Connection | Switch Condition | Specified Condition |
| 4 (TB) - 1 (E) | OFF (Not pushed) | 10 kΩ or higher |
| 4 (TB) - 1 (E) | ON (Pushed) | Below 23.4 Ω |
Inspect the switch illumination.
Connect the battery positive (+) lead to terminal 3 (ILL+) and the negative (-) lead to terminal 2 (ILL-), then check that the light comes on.