Home › ENGINE · 2GR-FE › ENGINE CONTROL SYSTEM › CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY

CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY > INSPECTION

for Preparation Click here



1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY


    A095415E04
  1. Measure the resistance of the oil control valve.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (+B) - 2 (GND)
    6.9 to 7.9 Ω at 20°C (68°F)

    If the result is not as specified, replace the oil control valve assembly.



    A095391E03
  1. Check the operation.

    1. Connect the battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.

      OK:
      Condition
      Specified Condition
      Battery positive (+) voltage is applied
      Valve moves in black arrow direction shown in illustration
      Battery positive (+) voltage is cut off
      Valve moves in white arrow direction shown in illustration

      If the result is not as specified, replace the oil control valve.

      NOTICE:
      If the valve cannot return properly because of foreign matter intrusion, a small leakage in the advanced direction may occur and a DTC may be output.