Home
›
ENGINE · 1AZ-FE
›
ENGINE CONTROL SYSTEM
›
KNOCK SENSOR
KNOCK SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT KNOCK SENSOR
Measure the resistance of the sensor.
Standard resistance:
Tester Connection
Specified Condition
1 (Ground) - 2 (Output)
120 to 280 kΩ at 20°C (68°F)
If the result is not as specified, replace the knock sensor.