Home › ENGINE · 2AZ-FE › ENGINE CONTROL SYSTEM › KNOCK SENSOR

KNOCK SENSOR > INSPECTION

for Preparation Click here



1. INSPECT KNOCK SENSOR


    A093606E04
  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (Ground) - 2 (Output)
    120 to 280 kΩ at 20°C (68°F)

    If the result is not as specified, replace the knock sensor.