ECM > INSTALLATION |
| 1. INSTALL ECM |
![]() |
Install the 2 brackets to the ECM with the 4 screws.
![]() |
Connect the 2 ECM connectors.
Connect the 2 ECM connectors and lower the 2 levers.
![]() |
Install the ECM with the 3 bolts.
| 2. INSTALL AIR CLEANER CASE |
![]() |
Install the air cleaner case with the 3 bolts.
Connect the harness clamp.
| 3. INSTALL AIR CLEANER CAP SUB-ASSEMBLY |
Install the air cleaner filter element onto the air cleaner case.
![]() |
Insert the hinge part of the air cleaner cap into the air cleaner case, then hang the 2 hook clamps.
![]() |
Tighten the No. 1 air cleaner hose clamp.
Connect the No. 2 ventilation hose to the air cleaner hose.
Connect the 2 wire harness clamps and 2 vacuum hoses.
Connect the VSV (intake air control) connector.
Connect the mass air flow meter connector.
| 4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 5. PERFORM REGISTRATION |
When replacing the ECM, perform the vehicle stability control system recognition in the ECM (Click here).
| 6. RESET MEMORY |
When replacing the ECM, perform the RESET MEMORY procedure (A/T initialization) (Click here).