CHARGING SYSTEM (w/ Entry and Start System) > ON-VEHICLE INSPECTION |
| 1. CHECK BATTERY CONDITION |
Check the battery for damage or deformation. If severe damage, deformation or leakage is found, replace the battery.
Check the electrolyte quantity of each cell.
For maintenance-free batteries:
![]() |
For non-maintenance-free batteries:
Check the battery voltage.
Turn the engine switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the battery.
![]() |
Measure the battery voltage between the negative (-) and positive (+) terminals of the battery.
| 2. INSPECT BATTERY TERMINAL AND FUSE |
Check that the battery terminals are not loose or corroded.
If the terminals are corroded, clean the terminals.
Measure the resistance of the H-fuses and fuses.
| 3. INSPECT V-RIBBED BELT |
![]() |
Check the belt for wear, cracks or other signs of damage.
If any of the following defects is found, replace the V-ribbed belt.
![]() |
Check that the belt fits properly in the ribbed grooves.
![]() |
Check the V-ribbed belt deflection and tension.
| Item | Specified Condition |
| New belt | 7.0 to 8.2 mm (0.276 to 0.323 in.) |
| Used belt | 7.6 to 10.0 mm (0.299 to 0.394 in.) |
| Item | Specified Condition |
| New belt | 700 to 800 N (70 to 80 kgf, 157.4 to 179.8 lbf) |
| Used belt | 550 to 750 N (55 to 75 kgf, 123.6 to 168.6 lbf) |
| 4. INSPECT GENERATOR WIRING |
Check that the wiring is in good condition.
If the wiring is damaged, repair or replace the generator wire.
| 5. CHECK FOR ABNORMAL NOISES |
Check that no abnormal noises are heard from the generator while the engine is running.
If there is abnormal noise, replace the pulley or generator.
| 6. INSPECT CHARGE WARNING LIGHT CIRCUIT |
Turn the engine switch on (IG). Check that the charge warning light comes on.
Start the engine and check that the light goes off.
If the light does not operate as specified, troubleshoot the charge warning light circuit.
| 7. INSPECT CHARGING CIRCUIT WITHOUT LOAD |
![]() |
Connect the voltmeter and ammeter to the charging circuit as follows.
Disconnect the wire from terminal B of the generator, and then connect it to the negative (-) lead of the ammeter.
Connect the positive (+) lead of the ammeter to terminal B of the generator.
Connect the positive (+) lead of the voltmeter to the terminal B of the generator.
Ground the negative (-) lead of the voltmeter.
Check the charging circuit.
Keep the engine speed at 2000 rpm and check the reading on the ammeter and voltmeter.
| 8. INSPECT CHARGING CIRCUIT WITH LOAD |
With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the "HI" position.
Check the reading on the ammeter.