COMPRESSOR AND PULLEY (for 2AZ-FE) > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
When replacing the compressor and magnetic clutch with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new compressor and magnetic clutch before installation.
| 2. INSTALL COOLER COMPRESSOR ASSEMBLY |
![]() |
w/o Stud Bolt:
Install the cooler compressor with the 4 bolts.
w/ Stud Bolt:
Install the cooler compressor with the 3 bolts and nut.
Connect the connector.
| 3. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE (w/ Bracket) |
![]() |
Remove the attached vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.
Install the O-ring on the cooler refrigerant discharge hose.
Install the cooler refrigerant discharge hose on the cooler compressor with the bolt.
| 4. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE (w/o Bracket) |
![]() |
Remove the attached vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.
Install the O-ring on the cooler refrigerant discharge hose.
Install the cooler refrigerant discharge hose on the cooler compressor with the bolt.
| 5. INSTALL NO. 1 COOLER REFRIGERANT SUCTION HOSE |
![]() |
Remove the attached vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the cooler compressor.
Install the O-ring on the cooler refrigerant suction hose.
Install the cooler refrigerant suction hose on the cooler compressor with the bolt.
| 6. INSTALL FAN & GENERATOR V BELT |
![]() |
Using SST and 19 mm socket wrench, loosen the V-ribbed belt tensioner arm clockwise, then install the fan and generator V belt.
| 7. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 8. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 9. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging the refrigerant.
| 10. CHECK FOR LEAKAGE OF REFRIGERANT |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:
![]() |
Using a gas leak detector, check the refrigerant line for leakage.
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the connector and leave the pressure switch on for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.