COMPRESSOR AND PULLEY (for 1AZ-FE) > REMOVAL |
| 1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
Start the engine.
Turn the A/C switch on.
Operate the cooler compressor while the engine speed is approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the compressor oil remaining in each component into the cooler compressor.
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
| 2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 3. DISCONNECT NO. 1 COOLER REFRIGERANT SUCTION HOSE |
![]() |
Remove the bolt and disconnect the cooler refrigerant suction hose from the cooler compressor.
Remove the O-ring from the cooler refrigerant suction hose.
| 4. DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the bolt and disconnect the cooler refrigerant discharge hose from the cooler compressor.
Remove the O-ring from the cooler refrigerant discharge hose.
| 5. REMOVE FAN & GENERATOR V BELT |
![]() |
Using SST 19 mm socket wrench, loosen the V-ribbed belt tensioner arm clockwise, then remove the fan and generator V belt.
| 6. REMOVE COOLER COMPRESSOR ASSEMBLY |
![]() |
Disconnect the connector.
w/ Stud Bolt:
Remove the 3 bolts, nut and cooler compressor.
w/o Stud Bolt:
Remove the 4 bolts and cooler compressor.