CIRCUIT OPENING RELAY > ON-VEHICLE INSPECTION |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. INSPECT INSTRUMENT PANEL JUNCTION BLOCK |
Measure the resistance between the terminals.

| Tester Connection | Specified Condition |
| 1B-11 - 1A-8 | 10 kΩ or higher |
| 1B-11 - 1A-8 | Below 1 Ω (when battery voltage is applied to terminals 1E-5 and 1D-1) |
| 3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |