DTC B1411/11 Room Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1411/11 | Open or short in room temperature sensor circuit |
|

| 1.READ VALUE USING INTELLIGENT TESTER (ROOM TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Room Temp | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) | Actual room temperature is displayed | Open circuit: -6.5°C (20.3°F) Short circuit: 57.25°C (135.05°F) |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT ROOM TEMPERATURE SENSOR |
![]() |
Remove the room temperature sensor.
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
| 1 (ST+) - 2 (ST-) | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 1 (ST+) - 2 (ST-) | 15°C (59°F) | 2.45 to 2.88 kΩ |
| 1 (ST+) - 2 (ST-) | 20°C (68°F) | 1.95 to 2.30 kΩ |
| 1 (ST+) - 2 (ST-) | 25°C (77°F) | 1.60 to 1.80 kΩ |
| 1 (ST+) - 2 (ST-) | 30°C (86°F) | 1.28 to 1.47 kΩ |
| 1 (ST+) - 2 (ST-) | 35°C (95°F) | 1.00 to 1.22 kΩ |
| 1 (ST+) - 2 (ST-) | 40°C (104°F) | 0.80 to 1.00 kΩ |
| 1 (ST+) - 2 (ST-) | 45°C (113°F) | 0.65 to 0.85 kΩ |
| 1 (ST+) - 2 (ST-) | 50°C (122°F) | 0.50 to 0.70 kΩ |
| 1 (ST+) - 2 (ST-) | 55°C (131°F) | 0.44 to 0.60 kΩ |
| 1 (ST+) - 2 (ST-) | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the E24 sensor connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| E24-1 (ST+) - E41-29 (TR) | Below 1 Ω |
| E24-2 (ST-) - E41-34 (SG-1) | Below 1 Ω |
| E24-1 (ST+) - Body ground | 1 MΩ or higher |
| E24-2 (ST-) - Body ground | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||