DTC B1412/12 Ambient Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1412/12 | Open or short in ambient temperature sensor circuit |
|

| 1.READ VALUE USING INTELLIGENT TESTER (AMBI TEMP SENS) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Ambi Temp Sens | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | Open circuit: -23.3°C (-9.94°F) Short circuit: 65.95°C (150.71°F) |
| Result | Proceed to |
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT AMBIENT TEMPERATURE SENSOR |
![]() |
Remove the ambient temperature sensor.
Measure the resistance of the sensor.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 1 - 2 | 15°C (50°F) | 2.45 to 2.88 kΩ |
| 1 - 2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| 1 - 2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| 1 - 2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| 1 - 2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| 1 - 2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| 1 - 2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| 1 - 2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| 1 - 2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| 1 - 2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (AMBIENT TEMPERATURE SENSOR - COMBINATION METER) |
![]() |
Disconnect the A24 sensor connector.
Disconnect the E22 meter connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| A24-2 (OT+) - E22-23 (TEMP) | Below 1 Ω |
| A24-1 (OT-) - E22-11 (TX1+) | Below 1 Ω |
| A24-2 (OT+) - Body ground | 1 MΩ or higher |
| A24-1 (OT-) - Body ground | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||