DTC    B1423/23    Pressure Sensor Circuit

for Preparation Click here


DESCRIPTION

This DTC is output when the refrigerant pressure is either extremely low (0.19 MPa [2.0 kgf/cm2, 28 psi] or less) or extremely high (3.14 MPa [32.0 kgf/cm2, 455 psi] or more). The air conditioning pressure sensor, which is installed on the pipe of the high pressure side, detects the refrigerant pressure and sends refrigerant pressure signals to the air conditioning amplifier. The air conditioning amplifier determines the pressure from the signals in accordance with the sensor characteristics, and controls the compressor accordingly.

DTC No.
DTC Detection Condition
Trouble Area
B1423/23
Open or short in air conditioning pressure sensor circuit
  1. Air conditioning pressure sensor
  2. Harness and connector between air conditioning pressure sensor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E115012E02


INSPECTION PROCEDURE

1.CHECK REFRIGERANT
E123523E01
  1. Check the sight glass of the cooler unit refrigerant liquid pipe.

    1. Prepare the vehicle in accordance with the chart below.
      Item
      Condition
      Engine Speed
      1500 rpm
      Vehicle Doors
      Fully open
      Temperature Setting
      MAX COLD
      Blower Speed
      HI
      A/C Switch
      ON

    2. Compare the sight glass to the following chart.

      Item
      Symptom
      Amount of Refrigerant
      Corrective Procedures
      1
      Bubbles visible
      Insufficient*
      1. Check for gas leakage and repair if necessary
      2. Add refrigerant until bubbles disappear
      2
      No bubbles visible
      Empty, insufficient or too much
      Refer to items 3 and 4
      3
      No temperature difference between compressor inlet and outlet
      Empty or nearly empty
      1. Check for gas leakage with gas leak detector and repair if necessary
      2. Add refrigerant until bubbles disappear
      4
      Considerable temperature difference between compressor inlet and outlet
      Correct or too much
      Refer to items 5 and 6
      5
      Refrigerant becomes clear immediately after A/C turned OFF
      Too much
      1. Drain or discharge refrigerant
      2. Bleed air and supply proper amount of purified refrigerant
      6
      Refrigerant foams and then becomes clear immediately after A/C turned OFF
      Correct
      -

      HINT:
      *: If the ambient temperature is higher than usual but cooling is sufficient, bubbles in the sight glass are permissible.



NG
CHARGE REFRIGERANT
OK


2.READ VALUE USING INTELLIGENT TESTER (REG PRESS SENS)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch ON.

  1. Select the item below in the Data List, and read the value displayed on the intelligent tester.


Air conditioning amplifier:

Item
Measure Item / Display
(Range)
Normal Condition
Diagnostic Note
Reg Press Sens
Regulator pressure sensor /
Min.: 0 MPaG
Max.: 3.187 MPaG
Actual regulator pressure is displayed
-

OK:
The display is as specified in the normal condition column.


Result:

Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


3.CHECK WIRE HARNESS (PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER)
E115804E10
  1. Disconnect the A32 pressure sensor connector.

  1. Disconnect the E41 amplifier connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    A32-3 (+) - E41-10 (S5-3)
    Below 1 Ω
    A32-2 (PR) - E41-9 (PRE)
    Below 1 Ω
    A32-1 (-) - E41-13 (SG-2)
    Below 1 Ω
    A32-3 (+) - Body ground
    1 MΩ or higher
    A32-2 (PR) - Body ground
    1 MΩ or higher
    A32-1 (-) - Body ground
    1 MΩ or higher



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


4.CHECK AIR CONDITIONING AMPLIFIER
E115805E05
  1. Remove the air conditioning amplifier with its connectors still connected.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Tester Connection
    Specified Condition
    E41-13 (SG-2) - Body ground
    Below 1 Ω

  1. Turn the ignition switch on (IG).

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    E41-10 (S5-3) - E41-13 (SG-2)
    4.5 to 5.5 V



NG
REPLACE AIR CONDITIONING AMPLIFIER
OK


5.INSPECT AIR CONDITIONING PRESSURE SENSOR
E115949E03
  1. Turn the A/C switch ON.

  1. Disconnect the A32 sensor connector.

  1. Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 3 and the negative (-) lead to terminal 1. Then connect the voltmeter's positive (+) lead to terminal 2 and the negative (-) lead to terminal 1. Measure the voltage.

    OK:
    The voltage changes in accordance with the refrigerant pressure as shown in the graph.



NG
REPLACE AIR CONDITIONING PRESSURE SENSOR
OK

REPLACE AIR CONDITIONING AMPLIFIER