AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Air Conditioning Control Panel does not Operate |

| 1.CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND) |
![]() |
Disconnect the air conditioning control assembly connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| E26-7 (GND) - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY) |
![]() |
Disconnect the E26 air conditioning control assembly connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| E26-7 (GND) - E26-2 (IG+) | Ignition switch on (IG) | 10 to 14 V |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - AIR CONDITIONING CONTROL) |
![]() |
Disconnect the E26 control connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| E41-37 (LIN1) - E26-11 (LIN1) | Below 1 Ω |
|
| ||||
| OK | |
| 4.REPLACE AIR CONDITIONING CONTROL ASSEMBLY |
Replace the air conditioning control with a new or properly functioning one.
Operate the air conditioning control to check that it functions properly.
| Result | Proceed to |
| Air conditioning control malfunctions | A |
| Air conditioning control functions properly | B |
|
| ||||
| A | ||
| ||