AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Air Conditioning Control Panel does not Operate |

| 1.CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND) |
![]() |
Disconnect the E109 air conditioning control assembly connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| E109-8 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY) |
![]() |
Disconnect the E109 air conditioning control assembly connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Switch Condition | Specified Condition |
| E109-2 (IG+) - E109-8 (GND) | Ignition switch on (IG) | 11 to 14 V |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - AIR CONDITIONING CONTROL) |
![]() |
Disconnect the E109 control connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connector.
| Tester Connection | Condition | Specified Condition |
| E41-37 (LIN1) - E109-12 (LIN1) | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.REPLACE AIR CONDITIONING CONTROL ASSEMBLY |
Replace the air conditioning control with a new or properly functioning one.
Operate the air conditioning control to check that it functions properly.
|
| ||||
| OK | ||
| ||