Home › BODY ELECTRICAL › DOOR LOCK › POWER DOOR LOCK CONTROL SYSTEM

DTC    B1249    Double Locking ECU Communication Stop

for Preparation Click here


DESCRIPTION

DTC B1249 is output when the communication between the double door lock ECU and the main body ECU stops for more than 10 seconds.

DTC No.
DTC Detection Condition
Trouble Area
B1249
No communication from double door lock ECU for more than 10 seconds
  1. Aggregation ECU box (Double door lock ECU)
  2. Main body ECU
  3. Wire harness

WIRING DIAGRAM


E123927E02


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (COMMUNICATION DOUBLE LOCKING)
  1. Check the Data List to ensure the proper operation of the double door lock ECU.

    Main body ECU 
    Item
    Measurement Item / Display (Range)
    Normal Condition
    Diagnostic Note
    Communication Double Locking
    Connection status between double door lock ECU and main body ECU / OK or STOP
    OK: Connection
    STOP: No connection
    -

    OK:
    Doors can lock / unlock.



OK
REPLACE INSTRUMENT PANEL JUNCTION BLOCK (MAIN BODY ECU)
NG


2.CHECK WIRE HARNESS (DOUBLE DOOR LOCK ECU - BODY ECU, BATTERY AND BODY GROUND)


    B123859E03
  1. Disconnect the E82 double door lock ECU connector.

  1. Disconnect the E18 main body ECU connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    E82-9 (MPX1) - E18-23 (LIN2)
    Below 1 Ω
    E82-9 (MPX1) or E18-23 (LIN2) - Body ground
    10 kΩ or higher
    E82-14 (GND) - Body ground
    Below 1 Ω

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Specified Condition
    E82-1 (+B) - Body ground
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECU AGGREGATION BOX (DOUBLE DOOR LOCK ECU)