Home › ENGINE · 2GR-FE › EMISSION CONTROL › PURGE VALVE

PURGE VALVE > INSPECTION

for Preparation Click here



1. INSPECT PURGE VSV


    A139297
  1. Measure the resistance of the purge VSV.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    23 to 26 Ω
    1 - Body ground
    2 - Body ground
    Always
    10 MΩ or higher

    If the result is not as specified, replace the purge VSV.



  1. Check the operation of the purge VSV.



      A139298E01
    1. Check that air does not flow from port E to port F.



    2. A139299E01
    3. Apply battery voltage across the terminals.

    4. Check that air flows from port E to port F.
      If the result is not as specified, replace the purge VSV.