PARK / NEUTRAL POSITION SWITCH > INSPECTION |
| 1. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (PL) - 2 (RB) | P position | Below 1 Ω |
| 6 (PL) - 2 (RB) | Not in P position | 10 kΩ or higher |
| 1 (RL) - 2 (RB) | R position | Below 1 Ω |
| 1 (RL) - 2 (RB) | Not in R position | 10 kΩ or higher |
| 9 (NL) - 2 (RB) | N position | Below 1 Ω |
| 9 (NL) - 2 (RB) | Not in N position | 10 kΩ or higher |
| 7 (DL) - 2 (RB) | D position | Below 1 Ω |
| 7 (DL) - 2 (RB) | Not in D position | 10 kΩ or higher |
| 3 (2L) - 2 (RB) | 2 position | Below 1 Ω |
| 3 (2L) - 2 (RB) | Not in 2 position | 10 kΩ or higher |
| 8 (LL) - 2 (RB) | L position | Below 1 Ω |
| 8 (LL) - 2 (RB) | Not in L position | 10 kΩ or higher |