Home › TRANSMISSION ยท U140F AUTOMATIC TRANSAXLE › SHIFT LOCK SYSTEM

SHIFT LOCK SYSTEM > INSPECTION

for Preparation Click here



1. INSPECT KEY INTERLOCK SOLENOID


C127834E01
  1. Disconnect the solenoid connector.

  1. Connect the battery's positive (+) lead to terminal 1 (UN+) and the battery's negative (-) lead to terminal 2 (UN-).
    Check that the operating noise of the solenoid can be heard.
    If the result is not as specified, replace the solenoid.