Home
›
TRANSMISSION ยท U151F AUTOMATIC TRANSAXLE
›
DIFFERENTIAL CASE
DIFFERENTIAL CASE > INSPECTION
for Preparation
Click here
1. INSPECT DIFFERENTIAL SIDE GEAR BACKLASH
Using a dial indicator, measure the backlash of the side gear.
Standard backlash:
0.05 to 0.20 mm (0.0020 to 0.0070 in.)
Standard thrust washer thickness:
1.625 mm (0.0640 in.)
1.725 mm (0.0679 in.)
1.825 mm (0.0719 in.)