EXHAUST PIPE > INSTALLATION |
| 1. INSTALL FRONT EXHAUST PIPE ASSEMBLY |
![]() |
Using a vernier caliper, measure the free length of the compression spring.
![]() |
Install a new gasket by hand so that its surface is flush with the exhaust manifold.
Install the front exhaust pipe with the 2 compression springs and 2 bolts.

| 2. INSTALL CENTER EXHAUST PIPE ASSEMBLY |
![]() |
Install a new gasket onto the front exhaust pipe.
Connect the 3 exhaust pipe supports, and install the center exhaust pipe.
Install the 2 bolts.

| 3. INSTALL TAILPIPE ASSEMBLY |
![]() |
Using a vernier caliper, measure the free length of the compression spring.
![]() |
Install a new gasket by hand so that its surface is flush with the center exhaust pipe.
Connect the 2 exhaust pipe supports, and install the tailpipe.
Install the 2 compression springs and 2 bolts.

| 4. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2) |
![]() |
Using SST, install the sensor to the front exhaust pipe.
Connect the sensor connector.
| 5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
| 6. CHECK FOR EXHAUST GAS LEAKS |