POWER DOOR LOCK CONTROL SYSTEM > Only Back Door LOCK / UNLOCK Functions do not Operate |

| 1.INSPECT BACK DOOR WITH MOTOR LOCK ASSEMBLY |
![]() |
Apply the battery voltage to the door lock motor and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → 4 (ACT+) Battery negative (-) → 1 (ACT-) | Lock |
| Battery positive (+) → 1 (ACT-) Battery negative (-) → 4 (ACT+) | Unlock |
Measure the resistance of the door lock position switch.
| Tester Connection | Switch Condition | Specified Condition |
| 7 (S) - 8 (E) | Lock | 10 kΩ or higher |
| 7 (S) - 8 (E) | Unlock | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (ECU - DOOR LOCK) |

w/ Double Locking System:
Disconnect the S10 door lock connector.
Disconnect the IH junction block connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| S10-1 (ACT-) - IH-18 (ACT-) | Below 1 Ω |
| S10-4 (ACT+) - IH-17 (ACT+) | Below 1 Ω |
| S10-7 (S) - E18-10 (LSWP) | Below 1 Ω |
| S10-8 (E) - Body ground | Below 1 Ω |
w/o Double Locking System:
Disconnect the S10 door lock connector.
Disconnect the E18 ECU connector.
Disconnect the IH junction block connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| S10-1 (ACT-) - IH-18 (ACT-) | Below 1 Ω |
| S10-4 (ACT+) - IH-17 (ACT+) | Below 1 Ω |
| S10-7 (S) - E18-13 (LSWB) | Below 1 Ω |
| S10-8 (E) - Body ground | Below 1 Ω |
|
| ||||
| OK | ||
| ||