Home › BODY ELECTRICAL › DOOR LOCK › POWER DOOR LOCK CONTROL SYSTEM

POWER DOOR LOCK CONTROL SYSTEM > Only Rear Door RH LOCK / UNLOCK Functions do not Operate

for Preparation Click here


DESCRIPTION

The main body ECU receives lock / unlock switch signals and activates the door lock motor accordingly.

WIRING DIAGRAM


E114762E03


INSPECTION PROCEDURE

1.INSPECT REAR DOOR WITH MOTOR LOCK ASSEMBLY RH


    E123891E01
  1. for LHD, RHD (w/o Double Locking System):

    1. Apply the battery voltage to the door lock motor and check the operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → 4 (L)
      Battery negative (-) → 1 (UL)
      Lock
      Battery positive (+) → 1 (UL)
      Battery negative (-) → 4 (L)
      Unlock



    E123915E01
  1. for RHD (w/ Double Locking System):

    1. Apply the battery voltage to the door lock motor and check the operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → 4 (L)
      Battery negative (-) → 3 (UL)
      Lock
      Battery positive (+) → 3 (UL)
      Battery negative (-) → 4 (L)
      Unlock



NG
REPLACE REAR DOOR WITH MOTOR LOCK ASSEMBLY RH
OK


2.CHECK WIRE HARNESS (DOOR LOCK - ECU)

E123924E04

  1. Disconnect the I4 door lock connector.

  1. Disconnect the IH junction block connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    for LHD, RHD (w/o Double Locking System):
    Tester Connection
    Specified Condition
    I4-1 (UL) - IH-18 (ACT-)
    Below 1 Ω
    I4-4 (L) - IH-17 (ACT+)
    Below 1 Ω
    for RHD (w/ Double Locking System):
    Tester Connection
    Specified Condition
    I4-3 (UL) - IH-18 (ACT-)
    Below 1 Ω
    I4-4 (L) - IH-17 (ACT+)
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR (MAIN BODY ECU)
OK

REPLACE INSTRUMENT PANEL JUNCTION BLOCK (MAIN BODY ECU)