YAW RATE AND DECELERATION SENSOR > INSPECTION |
| 1. CHECK YAW RATE SENSOR OR DECELERATION SENSOR |
Check the yaw rate sensor or deceleration sensor.
Under any of the following conditions, replace the sensor with a new one.
| 2. INSPECT DECELERATION SENSOR (w/o VSC) |
![]() |
Connect 3 dry cell batteries of 1.5 V in series (approximately 4.5 V total).
Connect the batteries' positive (+) lead to terminal 3 (VGS) and the negative (-) lead to terminal 2 (GGND).
Connect the voltmeter's positive (+) lead to the negative (-) lead of the batteries, and the negative (-) lead to terminal 1 (GL1).
Check the output voltage of terminal 1 (GL1) when the sensor is tilted forward and rearward.
| Tester Connection | Sensor Position | Specified Condition |
| 1 (GL1) - Battery's negative (-) lead | Horizontal | Approx. 2.25 V |
| 1 (GL1) - Battery's negative (-) lead | Tilted forward | Approx. 0.45 to 2.25 V |
| 1 (GL1) - Battery's negative (-) lead | Tilted rearward | Approx. 2.25 to 4.05 V |