1. INSPECT HEATED OXYGEN SENSOR (for Sensor 2)


    A124800E01
  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Specified Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    -
    10 kΩ or higher

    If the resistance is not as specified, replace the sensor.