HEATED OXYGEN SENSOR > INSPECTION |
| 1. INSPECT HEATED OXYGEN SENSOR (for Sensor 2) |
![]() |
Measure the resistance of the sensor.
| Tester Connection | Specified Condition | Specified Condition |
| 1 (HT1B) - 2 (+B) | 20°C (68°F) | 11 to 16 Ω |
| 1 (HT1B) - 4 (E2) | - | 10 kΩ or higher |