Home
›
ENGINE · 2AZ-FE
›
EMISSION CONTROL
›
HEATED OXYGEN SENSOR
HEATED OXYGEN SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
Measure the resistance of the sensor.
Standard resistance:
Tester Connection
Specified Condition
1 (HT1B) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
1 (HT1B) - 4 (E2)
10 kΩ or higher
If the resistance is not as specified, replace the sensor.