POWER DOOR LOCK CONTROL SYSTEM > All Doors LOCK/UNLOCK Functions do not Operate Via Master Switch, Driver Side Door Key Cylinder |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (DOOR LOCK) |
Select the Active Test, use the intelligent tester to generate a control command, and then check that the doors lock / unlock.
| Item | Test Details | Diagnostic Note |
| DOOR LOCK | Operate door lock motor LOCK / UNLOCK | - |
|
| ||||
| NG | |
| 2.INSPECT FUSE (ECU - B) |
Remove the ECU-B fuse from the engine room No. 2 relay block.
Measure the resistance of the fuse.
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (ECU - BATTERY AND BODY GROUND) |

Disconnect the IB and IE junction block connectors.
Measure the voltage of the wire harness side connector.
| Tester Connection | Specified Condition |
| IB-30 (BECU) - Body ground | 10 to 14 V |
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| IE-17 (GND1) - Body ground | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 4.CHECK DRIVER SIDE DOOR LOCK / UNLOCK OPERATION |
Proceed to the next step according to the symptom listed in the table below.
| Symptom | Proceed to |
| All doors cannot be locked / unlocked at once using door control switch on power window regulator master switch. | A |
| All doors cannot be locked / unlocked at once using door key cylinder on driver side. | B |
| All doors cannot be locked / unlocked at once using both door control switch on master switch and door key cylinder on driver side. | C |
|
| ||||
|
| ||||
| A | |
| 5.READ VALUE USING INTELLIGENT TESTER (DOOR CONTROL SWITCH ON MASTER SWITCH) |
Use the Data List to check if the door control switch is functioning properly.
| Item | Measurement / Display (Range) | Normal Condition | Diagnostic Note |
| Door Lock SW-Lock | Door manual lock switch signal / ON or OFF | ON: Door control switch on power window regulator master switch is pushed to lock position OFF: Door control switch on power window regulator master switch is pushed | - |
| Door Lock SW-Unlock | Door manual unlock switch signal / ON or OFF | ON: Door control switch on power window regulator master switch is pushed to unlock position OFF: Door control switch on power window regulator master switch is pushed | - |
|
| ||||
| NG | |
| 6.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY |
![]() |
Remove the master switch.
Measure the resistance of the door control switch.
| Tester Connection | Switch Condition | Specified Condition |
| 2 (L) - 1 (E) | Lock | Below 80 Ω |
| 2 (L) - 1 (E) | OFF | 10 kΩ or higher |
| 9 (UL) - 1 (E) | Unlock | Below 80 Ω |
| 9 (UL) - 1 (E) | OFF | 10 kΩ or higher |
| Tester Connection | Switch Condition | Specified Condition |
| 2 (L) - 9 (E) | Lock | Below 80 Ω |
| 2 (L) - 9 (E) | OFF | 10 kΩ or higher |
| 8 (UL) - 9 (E) | Unlock | Below 80 Ω |
| 8 (UL) - 9 (E) | OFF | 10 kΩ or higher |
|
| ||||
| OK | |
| 7.CHECK WIRE HARNESS (MASTER SWITCH - ECU AND BODY GROUND) |

for LHD:
Disconnect the H2 master switch connector.
Disconnect the IH junction block connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| H2-2 (L) - IH-4 (L1) | Below 1 Ω |
| H2-2 (L) - Body ground | 10 kΩ or higher |
| IH-4 (L1) - Body ground | 10 kΩ or higher |
| H2-9 (UL) - IH-5 (UL1) | Below 1 Ω |
| H2-9 (UL) - Body ground | 10 kΩ or higher |
| IH-5 (UL1) - Body ground | 10 kΩ or higher |
| H2-1 (E) - Body ground | Below 1 Ω |
for RHD:
Disconnect the G8 master switch connector.
Disconnect the IH junction block connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| G8-2 (L) - IH-13 (L1) | Below 1 Ω |
| G8-2 (L) - Body ground | 10 kΩ or higher |
| IH-13 (L1) - Body ground | 10 kΩ or higher |
| G8-8 (UL) - IH-14 (UL1) | Below 1 Ω |
| G8-8 (UL) - Body ground | 10 kΩ or higher |
| IH-14 (UL1) - Body ground | 10 kΩ or higher |
| G8-9 (E) - Body ground | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 8.READ VALUE USING INTELLIGENT TESTER (DOOR KEY SWITCH) |
Use the Data List to check if the door key is functioning properly.
| Item | Measurement / Display (Range) | Normal Condition | Diagnostic Note |
| Door Key SW-Lock | Door key linked lock switch signal / ON or OFF | ON: Driver side door key cylinder is turned to lock position OFF: Driver side door key cylinder is not turned | - |
| Door Key SW-Unlock | Door key linked lock switch signal / ON or OFF | ON: Driver side door key cylinder is turned to unlock position OFF: Driver side door key cylinder is not turned | - |
|
| ||||
| NG | |
| 9.INSPECT FRONT DOOR WITH MOTOR LOCK ASSEMBLY (DRIVER SIDE) |
![]() |
for LHD:
Remove the front door lock.
Measure the resistance of the door lock and unlock switch.
| Tester Connection | Switch Condition | Specified Condition |
| 9 (L) -7 (E) | Lock | Below 1 Ω |
| 9 (L) -7 (E) | OFF | 10 kΩ or higher |
| 10 (UL) - 7 (E) | Unlock | Below 1 Ω |
| 10 (UL) - 7 (E) | OFF | 10 kΩ or higher |
![]() |
for RHD (w/o Double Locking System):
Remove the front door lock.
Measure the resistance of the door key lock and unlock switch operation.
| Tester Connection | Switch Condition | Specified Condition |
| 5 (UL) -8 (E) | Lock | Below 1 Ω |
| 5 (UL) -8 (E) | OFF | 10 kΩ or higher |
| 6 (L) - 8 (E) | Unlock | Below 1 Ω |
| 6 (L) - 8 (E) | OFF | 10 kΩ or higher |
![]() |
for RHD (w/ Double Locking System):
Remove the front door lock.
Measure the resistance of the door lock and unlock switch.
| Tester Connection | Switch Condition | Specified Condition |
| 5 (UL) -8 (E) | Lock | Below 1 Ω |
| 5 (UL) -8 (E) | OFF | 10 kΩ or higher |
| 6 (L) - 8 (E) | Unlock | Below 1 Ω |
| 6 (L) - 8 (E) | OFF | 10 kΩ or higher |
|
| ||||
| OK | |
| 10.CHECK WIRE HARNESS (MOTOR - ECU AND BODY GROUND) |

for LHD:
Disconnect the H5 door lock motor connector.
Disconnect the IH junction block connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| H5-9 (L) - IH-7 (L2) | Below 1 Ω |
| H5-9 (L) - Body ground | 10 kΩ or higher |
| IH-7 (L2) - Body ground | 10 kΩ or higher |
| H5-10 (UL) - IH-6 (UL2) | Below 1 Ω |
| H5-10 (UL) - Body ground | 10 kΩ or higher |
| IH-6 (UL2) - Body ground | 10 kΩ or higher |
for RHD:
Disconnect the G5 door lock motor connector.
Disconnect the IH junction block connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| G5-6 (L) - IH-16 (L2) | Below 1 Ω |
| G5-6 (L) - Body ground | 10 kΩ or higher |
| IH-16 (L2) - Body ground | 10 kΩ or higher |
| G5-5 (UL) - IH-15 (UL2) | Below 1 Ω |
| G5-5 (UL) - Body ground | 10 kΩ or higher |
| IH-15 (UL2) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||