METER / GAUGE SYSTEM > Entire Combination Meter does not Operate |

| 1.INSPECT FUSE (GAUGE2, ECU-B, IG2) |
Remove the GAUGE2 fuse from the instrument panel junction block.
Remove the ECU-B fuse from the No. 2 relay block.
Remove the IG2 fuse from the No. 1 relay block.
Measure the resistance of the fuses.
|
| ||||
| OK | |
| 2.INSPECT IG2 RELAY |
![]() |
Remove the IG2 relay from the No. 1 relay block.
Measure the resistance of the relay.
| Tester Connection | Specified Condition |
| 3 - 5 | 10 kΩ or higher |
| 3 - 5 | Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (COMBINATION METER - BATTERY AND BODY GROUND) |
![]() |
Disconnect the E22 meter connector.
Measure the voltage of the wire harness side connector.
| Tester Connection | Switch Condition | Specified Condition |
| E22-22 (B) - Body ground | Always | 11 to 14 V |
| E22-21 (IG+) - Body ground | Ignition switch on (IG) | 11 to 14 V |
Measure the resistance of the wire harness side connector.
| Tester Connection | Specified Condition |
| E22-33 (ET) - Body ground | Below 1 Ω |
|
| ||||
| OK | ||
| ||