METER / GAUGE SYSTEM > Operating Light Control Rheostat does not Change Light Brightness |

| 1.READ VALUE USING DATA LIST (Rheostat value (A/D)) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and the tester ON.
Read the Data List according to the prompts displayed on the tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Rheostat value (A/D) | Light control rheostat volume / Min.: 0, Max.: 255 | Light control rheostat Min. position: 0 Light control rheostat Max. position: 255 | - |
|
| ||||
| OK | |
| 2.INSPECT LIGHT CONTROL RHEOSTAT |
![]() |
Remove the light control rheostat.
Measure the resistance of the rheostat.
| Tester Connection | Rheostat Position | Specified Condition |
| 1 (E) - 3 (RV) | Max. | 8 to 12 kΩ |
| 1 (E) - 3 (RV) | Mid. | 4.7 kΩ |
| 1 (E) - 3 (RV) | Min. | 0 to 50 Ω |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (COMBINATION METER - LIGHT CONTROL RHEOSTAT) |
![]() |
Disconnect the E22 meter connector.
Disconnect the E2 rheostat connector.
Measure the resistance of the wire harness side connectors.
| Tester Connection | Specified Condition |
| E22-26 (SW1) - E2-7 (T) | Below 1 Ω |
| E22-27 (SW2) - E2-3 (RV) | Below 1 Ω |
| E22-30 (TC) - E2-5 (TC) | Below 1 Ω |
| E22-34 (SW3) - E2-1 (E) | Below 1 Ω |
| E22-26 (SW1) or E2-7 (T) - Body ground | 8 to 12 kΩ |
| E22-27 (SW2) or E2-3 (RV) - Body ground | 8 to 12 kΩ (position Max.) |
| E22-30 (TC) or E2-5 (TC) - Body ground | Below 1 Ω (Tail cancel OFF) |
| E22-34 (SW3) or E2-1 (E) - Body ground | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||