1AZ-FE COOLING > SERVICE DATA |
| Condition | Specified Condition | |
| Valve opening temperature | 80 to 84°C (176 to 183°F) | |
| Valve lift | at 95°C (203°F) | 10 mm (0.39 in.) or more |
| Indication Mark | Motor Type | Condition | Specified Condition |
| A | 80 W | at 20°C (68°F) | 5.8 to 7.8 A |
| B, C | 160 W | at 20°C (68°F) | 11.7 to 14.7 A |
| Indication Mark | Motor Type | Condition | Specified Condition |
| A | 80 W | at 20°C (68°F) | 5.8 to 7.8 A |
| B | 120 W | at 20°C (68°F) | 8.4 to 10.4 A |
| C | 160 W | at 20°C (68°F) | 11.7 to 14.7 A |
| Tester Connection | Specified Condition |
| 3 - 5 | 10 Ω or higher |
| 3 - 5 | Below 1 Ω (When battery voltage is applied to terminals 1 and 2) |
| Tester Connection | Specified Condition |
| 3 - 4 | Below 1 Ω |
| 3 - 5 | 10 Ω or higher |
| 3 - 4 | 10 Ω or higher (When battery voltage is applied to terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (When battery voltage is applied to terminals 1 and 2) |
| Tester Connection | Specified Condition |
| 3 - 5 | 10 Ω or higher |
| 3 - 5 | Below 1 Ω (When battery voltage is applied to terminals 1 and 2) |
| Item | Specified Condition |
| Standard value (for brand-new cap) | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) |
| Minimum standard value (after using cap) | 78.5 kPa (0.8 kgf/cm2, 11.4 psi) |