Home › BODY ELECTRICAL › DOOR LOCK › ENTRY AND START SYSTEM

ENTRY AND START SYSTEM > Entry Functions do not Operate at All

for Preparation Click here


DESCRIPTION

When the entry functions do not operate at all, it is possible that the certification ECU is malfunctioning or that the wire harness leading to the certification ECU is short circuited.

WIRING DIAGRAM


B133570E01


INSPECTION PROCEDURE

1.CHECK KEY CANCEL FUNCTION
  1. Check that the key cancel function has been set (Click here).

    OK:
    Key cancel function is set.



OK
END (UNSET KEY CANCEL FUNCTION)
NG


2.CHECK WIRE HARNESS (CERTIFICATION ECU - BATTERY AND BODY GROUND)
B107456E37
  1. Disconnect the E63 ECU connector.

  1. Measure the resistance and voltage of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    E63-17 (E) - Body ground
    Below 1 Ω

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    E63-18 (IG) - Body ground
    Ignition switch on (IG)
    10 to 14 V
    Ignition switch off
    Below 1 V
    E63-1 (+B1) - Body ground
    Always
    10 to 14 V



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECU AGGREGATION BOX (CERTIFICATION ECU)