CONTINUOUSLY VARIABLE VALVE LIFT CONTROLLER > INSPECTION |
| 1. INSPECT CONTINUOUSLY VARIABLE VALVE LIFT CONTROLLER ASSEMBLY |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VALVEMATIC (ENG OFF) (Click here).
| Tester Operation | Specified Condition |
| Low | VALVEMATIC Current Angle is 100 to 120°CA and shaft extends |
| High | VALVEMATIC Current Angle is 250°CA or more and shaft retracts |