ACTIVE TORQUE CONTROL 4WD SYSTEM > CALIBRATION |
| DESCRIPTION |
When the 4WD control ECU is replaced with a normal one from another vehicle or the yaw rate sensor is replaced, perform calibration.
Follow the chart to perform calibration.
| Part Replaced | Necessary Operation |
| 4WD Control ECU (When replaced with a normal one from another vehicle) | Clear zero point calibration data |
| Yaw Rate Sensor |
|
| PERFORM CALIBRATION (When Using Intelligent Tester) |
Clear the zero point calibration data.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Chassis / Four Wheel Drive / Utility / Reset Memory.
Operate the intelligent tester to clear the data.
| PERFORM CALIBRATION (When not Using Intelligent Tester) |
Calibrate the 4WD control ECU by performing vehicle stability control system calibration.