Home › ENGINE · 3ZR-FAE › STARTING › STARTER CUT RELAY (w/ Entry and Start System)

STARTER CUT RELAY (w/ Entry and Start System) > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT STARTER CUT RELAY (ST CUT)


    B060778E54
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to terminals 1 and 2
    10 kΩ or higher
    Battery voltage applied to terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the relay.