Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › 3ZR-FAE EMISSION CONTROL

3ZR-FAE EMISSION CONTROL > SERVICE DATA



Purge VSV 
Tester Connection
Specified Condition
1 - 2
23 to 26 Ω at 20°C (68°F)
1 - VSV body
2 - VSV body
10 MΩ or higher

Air fuel ratio sensor 
Tester Connection
Specified Condition
1 (HA1A) - 2 (+B)
1.8 to 3.4 Ω at 20°C (68°F)
1 (HA1A) - 4 (A1A-)
10 kΩ or higher

Heated oxygen sensor (for LHD) 
Tester Connection
Specified Condition
2 (HT1B) - 1 (+B)
11 to 16 Ω at 20°C (68°F)
2 (HT1B) - 3 (E2)
10 kΩ or higher

Heated oxygen sensor (for RHD) 
Tester Connection
Specified Condition
1 (HT1B) - 2 (+B)
11 to 16 Ω at 20°C (68°F)
1 (HT1B) - 4 (E2)
10 kΩ or higher