Home › Engine / Hybrid System › 2AR-FE ENGINE CONTROL › SFI SYSTEM
NM30B0U _51 Engine / Hybrid System _008617 2AR-FE ENGINE CONTROL _0048043 SFI SYSTEM DE DETAILS F

2AR-FE ENGINE CONTROL  SFI SYSTEM  DETAILS  STARTER CONTROL (CRANKING HOLD FUNCTION)  


OPERATION


a.

When the driver pushes the engine switch once and the certification ECU (smart key ECU assembly) detects a start signal, the certification ECU (smart key ECU assembly) outputs ACCD and STAR signals and begins cranking. Also, the driver can continue cranking for up to 30 seconds by pushing and holding the engine switch.


b.

If the engine speed reaches approximately 500 rpm, the ECM will judge that the engine has started and will send a signal to the certification ECU (smart key ECU assembly) using CAN communication. The certification ECU (smart key ECU assembly) will then stop the operation of the starter.


c.

If CAN communication is cut between the certification ECU (smart key ECU assembly) and the ECM, the certification ECU (smart key ECU assembly) will receive an engine speed signal (NE) directly from the ECM and will stop the operation of the starter.


d.

This system cuts off the power current which activates the accessories while the engine is being cranked. This prevents the intermittent blinking of the accessory lights caused by the voltage instability that occurs during engine cranking.


e.

This system has the following protections:

·

The starter does not operate when the engine is operating normally.

·

If the engine switch is pushed and held, cranking will stop once the engine speed reaches a pre-determined level. This prevents the starter from over-revving.

·

If the engine does not start even after approximately 6 seconds of starter operation, the certification ECU (smart key ECU assembly) will cancel the starter relay output. Furthermore, if the engine does not start after the engine switch has been pushed and held and cranking has continued for 30 seconds, cranking will be canceled in order to protect the starter.

·

It will not be possible to operate the starter for 2 seconds after engine starting has failed and cranking has been canceled. This helps to protect the starter.


W100462
0.635,1.5 1.583,1.813 0.948,0.313 10 Engine Switch 3.323,1.438 3.719,1.802 0.396,0.365 10 ECM 4.146,1.281 4.979,1.625 0.833,0.344 10 CAN (V Bus) 1.99,3.219 2.729,3.552 0.74,0.333 10 ACC Relay 4.5,5.073 5.125,6.094 0.625,1.021 10 Starter Relay Assembly 1.49,5.177 2.615,5.563 1.125,0.385 10 Starter Assembly 5.625,0.698 6.021,1.063 0.396,0.365 10 SSW 5.729,3.406 6.896,4.531 1.167,1.125 10 Certification ECU (Smart Key ECU Assembly) 5.615,1.99 6.01,2.354 0.396,0.365 10 NE 5.604,2.469 6.229,2.76 0.625,0.292 10 ACCD 5.615,2.771 6.24,3.135 0.625,0.365 10 STAR 5.635,4.875 5.958,5.208 0.323,0.333 10 STA 5.604,5.552 5.927,5.813 0.323,0.26 10 STP 4.688,6.167 6.021,6.5 1.333,0.333 10 Stop Light Signal 4.542,2.927 5.531,4.156 0.99,1.229 10 Park/Neutral Position Switch Assembly

W102484
1.948,0.25 2.229,0.521 0.281,0.271 10 On 1.948,1.198 2.24,1.469 0.292,0.271 10 On 1.948,2.0 2.26,2.271 0.313,0.271 10 On 1.948,1.604 2.24,1.875 0.292,0.271 10 Off 1.958,0.677 2.24,0.948 0.281,0.271 10 Off 1.938,2.396 2.25,2.667 0.313,0.271 10 Off 0.479,0.427 1.385,0.813 0.906,0.385 10 Starter Signal 0.479,2.146 1.625,2.635 1.146,0.49 10 Accessory Power 0.49,1.396 1.396,1.781 0.906,0.385 10 Starter Relay 0.323,3.073 1.979,3.448 1.656,0.375 10 Engine Speed Signal (NE) 1.688,3.938 5.292,4.604 3.604,0.667 10 ECM determines that the engine has started successfully when the engine speed is approximately 500 rpm. 5.573,2.521 6.844,3.188 1.271,0.667 10 Successful Starting of Engine 5.594,3.229 6.573,3.896 0.979,0.667 10 Failed Starting of Engine