2AR-FE ENGINE CONTROL  SFI SYSTEM  P043E  Evaporative Emission System Leak Detection Reference Orifice Low Flow  P043F  Evaporative Emission System Reference Orifice High Flow  P2401  Evaporative Emission Leak Detection Pump Stuck OFF  P2402  Evaporative Emission Leak Detection Pump Stuck ON  P2419  Evaporative Emission System Switching Valve Control Circuit Low  


DTC SUMMARY

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P043E Evaporative Emission System Leak Detection Reference Orifice Low Flow Reference orifice clogged during key-off EVAP monitor
·

Canister pump module

·

Connector/wire harness (Canister pump module - ECM)

·

ECM


Comes on DTC stored DTC for Mexico Models
- Not apply
P043F Evaporative Emission System Reference Orifice High Flow Reference orifice high-flow during key-off EVAP monitor
·

Canister pump module

·

Connector/wire harness (Canister pump module - ECM)

·

ECM


Comes on DTC stored DTC for Mexico Models
- Not apply
P2401 Evaporative Emission Leak Detection Pump Stuck OFF Leak detection pump off malfunction during key-off EVAP monitor
·

Canister pump module

·

Connector/wire harness (Canister pump module - ECM)

·

ECM


Comes on DTC stored DTC for Mexico Models
- Not apply
P2402 Evaporative Emission Leak Detection Pump Stuck ON Leak detection pump on malfunction during key-off EVAP monitor
·

Canister pump module

·

Connector/wire harness (Canister pump module - ECM)

·

ECM


Comes on DTC stored DTC for Mexico Models
- Not apply
P2419 Evaporative Emission System Switching Valve Control Circuit Low Vent valve on (closed) malfunction during key-off EVAP monitor
·

Canister pump module

·

Connector/wire harness (Canister pump module - ECM)

·

ECM


Comes on DTC stored DTC for Mexico Models
- Not apply

HINT:

The reference orifice is located inside the canister pump module.


DTC No. Monitoring Item Detection Timing Detection Logic
P043E Reference orifice clogged While ignition switch off 2 trip
P043F Reference orifice high-flow
P2401 Leak detection pump stuck OFF
P2402 Leak detection pump stuck ON
P2419 Vent valve stuck closed

DESCRIPTION

The description can be found in EVAP (Evaporative Emission) System.

Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM>EVAP System

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer, 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve is turned off (vent) and EVAP system pressure is measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system is not between 70 kPa(abs) and 110 kPa(abs) [525 mmHg(abs) and 825 mmHg(abs)], ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally. 360 seconds
C EVAP system pressure measurement Vent valve is turned on (closed) to shut EVAP system.
Negative pressure (vacuum) is created in EVAP system, and EVAP system pressure is then measured.
Write down measured value as it will be used in leak check
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
15 minutes*
D Purge VSV monitor Purge VSV is opened and then EVAP system pressure is measured by ECM.
Large increase indicates normal.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check is performed by comparing first and second reference pressure measurements.
If stabilized system pressure is higher than second reference pressure, ECM determines that EVAP system is leaking.
60 seconds
- Final check Atmospheric pressure is measured and then monitoring result is recorded by ECM. -

*: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612
1.604,2.156 1.75,2.438 false 2.458,1.094 2.823,0.99 false 2.406,1.646 2.792,1.625 false 2.563,2.021 2.833,2.021 false 1.208,3.302 1.208,3.427 false 1.302,4.479 1.583,4.5 false 2.323,3.188 1.854,3.948 false 5.083,0.958 5.083,1.083 false 5.323,2.198 5.448,2.156 false 5.135,4.479 5.448,4.5 false 5.083,3.302 5.083,3.438 false 1.604,1.083 1.698,0.677 false 0.635,2.063 1.469,1.948 false 0.604,1.656 1.146,1.74 false 1.781,1.583 1.854,1.354 1.854,1.354 2.802,1.354 false 5.656,1.594 5.719,1.365 5.719,1.365 6.677,1.365 false 5.708,3.948 5.771,3.719 5.771,3.719 6.729,3.719 false 1.219,0.948 1.198,1.125 false 0.198,0.156 0.51,0.344 0.313,0.188 10 *a 0.229,2.719 0.594,2.906 0.365,0.188 10 *c 4.469,0.167 4.792,0.365 0.323,0.198 10 *b 3.542,3.625 3.792,3.813 0.25,0.188 10 *e 0.417,1.552 0.646,1.74 0.229,0.188 10 *7 4.469,2.698 4.792,2.885 0.323,0.188 10 *d 1.635,0.51 2.167,0.688 0.531,0.177 10 *9 2.854,0.917 3.49,1.094 0.635,0.177 10 *10 2.854,1.25 3.094,1.427 0.24,0.177 10 *3 2.854,1.552 3.24,1.729 0.385,0.177 10 *11 2.844,1.948 3.125,2.125 0.281,0.177 10 *12 0.469,2 0.698,2.208 0.229,0.208 10 *8 1.76,2.448 2.073,2.625 0.313,0.177 10 *5 1.135,3.458 1.427,3.635 0.292,0.177 10 *1 1.146,4.396 1.375,4.573 0.229,0.177 10 *6 2.333,3.063 3.094,3.24 0.76,0.177 10 *4 3.552,4.208 3.802,4.438 0.25,0.229 10 *f 5.01,1.104 5.302,1.281 0.292,0.177 10 *1 5.146,2.125 5.375,2.302 0.229,0.177 10 *6 5,3.458 5.229,3.635 0.229,0.177 10 *2 4.979,4.385 5.208,4.563 0.229,0.177 10 *6 6.75,3.646 7.031,3.823 0.281,0.177 10 *4 6.719,1.281 6.958,1.458 0.24,0.177 10 *3 1.115,1.135 1.406,1.313 0.292,0.177 10 *1
*1 Purge VSV: Off (Closed) *2 Purge VSV: On (Open)
*3 Vent Valve: Off (Vent) *4 Vent Valve: On (Closed)
*5 Leak Detection Pump: Off *6 Leak Detection Pump: On
*7 Reference Orifice (0.02 inch) *8 Canister Pressure Sensor
*9 Canister *10 Fuel Tank
*11 Canister Pump Module *12 Canister Filter
*a Operation A:
Atmospheric Pressure Measurement
*b Operation B, E:
Reference Pressure Measurement
*c Operation C:
EVAP System Pressure Measurement
*d Operation D:
Purge VSV Monitor
*e Atmospheric Pressure *f Negative Pressure


The leak detection pump creates negative pressure through the reference orifice (in operation B and E). When the system is normal, the EVAP pressure is between 97 to 100 kPa(abs) [726 to 750 mmHg(abs)]* and saturated within a minute. If not, the ECM interprets this as a malfunction. The ECM illuminates the MIL and stores a DTC if this malfunction is detected in consecutive drive cycles.

*: Typical value.

A283584
0.063,0.021 2.917,0.219 2.854,0.198 10 EVAP Pressure during EVAP key-off monitor 0.417,1.042 1.167,1.25 0.75,0.208 10 Vent Valve 0.385,0.521 1.167,0.75 0.781,0.229 10 Purge VSV 0.156,1.448 1.146,1.875 0.99,0.427 10 Leak Detection Pump 0.115,2.01 1.167,2.271 1.052,0.26 10 EVAP Pressure 0.208,2.406 1.167,2.604 0.958,0.198 10 101 kPa(abs) 0.198,2.76 1.083,3.01 0.885,0.25 10 100 kPa(abs) 0.25,3.792 1.167,4.063 0.917,0.271 10 97 kPa(abs) 0.469,4.063 1.167,4.323 0.698,0.26 10 Sequence 0.125,4.333 1.167,4.604 1.042,0.271 10 Time (Seconds) 1.677,4.313 1.927,4.5 0.25,0.188 10 60 2.49,4.313 2.823,4.5 0.333,0.188 10 360 3.5,4.313 4.667,4.5 1.167,0.188 10 Within 15 minutes 5.115,4.313 5.365,4.5 0.25,0.188 10 10 5.698,4.313 5.948,4.5 0.25,0.188 10 60 1.698,4.073 1.917,4.25 0.219,0.177 10 A 2.563,4.073 2.75,4.25 0.188,0.177 10 B 3.958,4.073 4.167,4.25 0.208,0.177 10 C 5.146,4.073 5.333,4.25 0.188,0.177 10 D 5.719,4.073 5.917,4.25 0.198,0.177 10 E 3.906,1.042 4.25,1.25 0.344,0.208 10 ON 3.906,1.563 4.25,1.75 0.344,0.188 10 ON 5.073,0.5 5.417,0.75 0.344,0.25 10 ON 3.729,2.635 4.167,2.833 0.438,0.198 10 : OK 3.729,2.99 4.583,3.177 0.854,0.188 10 : Malfunction 6.26,0.344 7,0.552 0.74,0.208 10 ON: Open 6.25,0.604 7.083,0.823 0.833,0.219 10 OFF: Closed 6.26,0.896 7.083,1.083 0.823,0.188 10 ON: Closed 6.26,1.167 7,1.427 0.74,0.26 10 OFF: Vent

MONITOR STRATEGY

Required Sensors/Components (Main) Canister pump module
Required Sensors/Components (Related) -
Frequency of Operation Once per driving cycle
Duration Within 7 minutes
MIL Operation 2 driving cycles
Sequence of Operation None

TYPICAL ENABLING CONDITIONS

Monitor runs whenever the following DTCs are not stored None
Atmospheric pressure 70 kPa(abs) [525 mmHg(abs)] or higher, and less than 110 kPa(abs) [825 mmHg(abs)]
Battery voltage 10.5 V or higher
Vehicle speed Less than 4 km/h (2.5 mph)
Ignition switch Off
Time after key-off 5, 7 or 9.5 hours
Canister pressure sensor malfunction (P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of following conditions met before key-off Conditions 1 and 2
1. Duration that vehicle is driven 5 minutes or more
2. EVAP purge operation Performed
Engine coolant temperature 4.4°C (40°F) or higher, and less than 35°C (95°F)
Intake air temperature 4.4°C (40°F) or higher, and less than 35°C (95°F)

TYPICAL MALFUNCTION THRESHOLDS

"Saturated" indicates that the EVAP pressure change is below 0.286 kPa(gauge) [2.145 mmHg(gauge)] in 60 seconds.

One of following conditions met -
EVAP pressure just after reference pressure measurement started Higher than -0.25 kPa(gauge) [-1.875 mmHg(gauge)]
Reference pressure Below -4.85 kPa(gauge) [-36.38 mmHg(gauge)]
Reference pressure -1.057 kPa(gauge) [-7.929 mmHg(gauge)] or higher
Reference pressure Not saturated within 360 seconds
Reference pressure difference between first and second 0.9 kPa(gauge) [6.751 mmHg(gauge)] or higher

MONITOR RESULT

CONFIRMATION DRIVING PATTERN

NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the Techstream. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is higher than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).



1.

Connect the Techstream to the DLC3.

2.

Turn the ignition switch to ON and turn the Techstream on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the Techstream on.

6.

Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

7.

After the "Evaporative System Check" is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

8.

Input the DTC: P043E, P043F, P2401, P2402 or P2419.

9.

Check the DTC judgment result.

Techstream Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.



10.

If the judgment result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs.

Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR

HINT:
·

If a permanent DTC is output, the system is malfunctioning.

·

If no permanent DTC is output, the system is normal.




PROCEDURE

1.GO TO EVAP SYSTEM

Result:
Proceed to
NEXT



NEXT

END