Refer to DTC P2757.
Click hereDrivetrain>U760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>P2757
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2759 | Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) | An open or short is detected in the shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic). | ·
Open or short in shift solenoid valve SLU circuit ·
Shift solenoid valve SLU ·
Wiring harness connector ·
ECM |
Comes on | DTC stored |
When an open or short in the shift solenoid valve SLU circuit is detected, the ECM determines there is a malfunction. The ECM will turn on the MIL and store the DTC.
| Related DTCs | P2759: Shift solenoid valve SLU/Range check |
| Required sensors/Components | Shift solenoid valve SLU |
| Frequency of operation | Continuous |
| Duration | 1 sec. |
| MIL operation | Immediate |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not stored | None |
| Ignition switch | ON |
| Starter | OFF |
| Battery voltage | 12 V or higher |
| Battery voltage | 10 V or higher and below 12 V |
| Target duty cycle | Less than 75% |
| Output duty cycle | 100% or more |
| Output duty cycle | More than 3% and less than 100% |
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Click hereDrivetrain>U760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION
Perform the universal trip to clear permanent DTCs.
Click hereDrivetrain>U760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>DTC CHECK / CLEAR
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B77-7 (SLU+) - B77-6 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| B77-7 (SLU+) - Body ground and other terminals | Always | 10 kΩ or higher |
| B77-6 (SLU-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the B78 wiring harness connector.
Disconnect the B77 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B78-14 (SLU+) - B77-7 (SLU+) | Always | Below 1 Ω |
| B78-5 (SLU-) - B77-6 (SLU-) | Always | Below 1 Ω |
| B78-14 (SLU+) or B77-7 (SLU+) - Body ground and other terminals | Always | 10 kΩ or higher |
| B78-5 (SLU-) or B77-6 (SLU-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Transmission Wire) |
Remove the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A-11 (SLU+) - A-5 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| A-11 (SLU+) - Body ground and other terminals | Always | 10 kΩ or higher |
| A-5 (SLU-) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Shift Solenoid Valve SLU |
Remove shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 1 ·
Battery negative (-) → Terminal 2 |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG