Home › Drivetrain › U760F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM
RM30B0U _52 Drivetrain _009030 U760F AUTOMATIC TRANSMISSION / TRANSAXLE _0049436 AUTOMATIC TRANSAXLE SYSTEM C

U760F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2769  Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  P2770  Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  


DESCRIPTION

Shift solenoid valve SL is turned on and off by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls operation of the lock-up clutch.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) The ECM detects a short in the shift solenoid valve SL circuit when shift solenoid valve SL is operated (2-trip detection logic).
·

Short in shift solenoid valve SL circuit

·

Shift solenoid valve SL

·

Wiring harness connector

·

ECM


Comes on DTC stored
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) The ECM detects an open in the shift solenoid valve SL circuit when shift solenoid valve SL is not operated (2-trip detection logic).
·

Open in shift solenoid valve SL circuit

·

Shift solenoid valve SL

·

Wiring harness connector

·

ECM


Comes on DTC stored

Fail-safe function:

If the ECM detects a malfunction, it turns shift solenoid valve SL off.

MONITOR DESCRIPTION

Based on the signals from the throttle position sensor, air flow meter and crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smooth torque converter engagement. Shift solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short circuit for shift solenoid valve SL, it will illuminate the MIL and store the DTC.

MONITOR STRATEGY

Related DTCs P2769: Shift solenoid valve SL/Range check (Low resistance)
P2770: Shift solenoid valve SL/Range check (High resistance)
Required sensors/Components Shift solenoid valve SL
Frequency of operation Continuous
Duration 1 time
MIL operation 2 driving cycles
Sequence of operation None

TYPICAL ENABLING CONDITIONS

All
The monitor will run whenever the following DTCs are not stored None
Battery voltage 8 V or higher
Ignition switch ON
Starter OFF

P2769: Range Check (Low Resistance)
Shift solenoid valve SL ON
Time after solenoid OFF to ON 0.008 sec. or more

P2770: Range Check (High Resistance)
Shift solenoid valve SL OFF
Time after solenoid ON to OFF 0.008 sec. or more

TYPICAL MALFUNCTION THRESHOLDS

P2769: Range Check (Low Resistance)
Intelligent power MOS diagnosis fail signals detected while the solenoid is operated Fail at solenoid resistance: 8 Ω or less

P2770: Range Check (High Resistance)
Intelligent power MOS diagnosis fail signals detected while the solenoid is not operated Fail at solenoid resistance: 100 kΩ or more

COMPONENT OPERATING RANGE

Shift solenoid valve SL Resistance: 11 to 15 Ω at 20°C (68°F)

WIRING DIAGRAM

C239278
5.677,4.271 6.104,4.448 0.427,0.177 10 false ECM 5.104,1.302 5.344,1.469 0.24,0.167 10 false SL 3.698,1.188 3.938,1.354 0.24,0.167 10 false SL 1.646,2.052 2.531,2.438 0.885,0.385 10 false Shift Solenoid Valve SL 1.115,3.5 2.427,3.677 1.313,0.177 10 false Transmission Wire 3.021,3.5 4.01,3.833 0.99,0.333 10 false Wiring Harness Connector 5.677,4.115 5.969,4.271 0.292,0.156 10 false B77 4.052,1.083 4.198,1.26 0.146,0.177 10 false 6 2.771,1.083 2.885,1.26 0.115,0.177 10 false 6 3.063,1.188 3.302,1.354 0.24,0.167 10 false SL 2.427,1.188 2.667,1.354 0.24,0.167 10 false SL 4.896,1.406 5.042,1.583 0.146,0.177 10 false 3 2.76,1.292 3.052,1.448 0.292,0.156 10 false A 3.969,1.313 4.385,1.469 0.417,0.156 10 false B78

CAUTION / NOTICE / HINT

NOTICE:
·

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>U760F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION

·


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL CIRCUIT)
a.
C267934
1.448,0.177 1.865,0.385 0.417,0.208 0.26,1.698 0.469,0.885 true 1.531,0.208 1.99,0.406 0.458,0.198 10 false B77 0.094,1.75 0.802,1.969 0.708,0.219 10 false 3 (SL) 0.104,0.104 0.417,0.302 0.313,0.198 10 false *a
*a Front view of wire harness connector
(to ECM)


Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B77-3 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

2.CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)
2.CHECK HARNESS AND CONNECTOR (WIRING HARNESS CONNECTOR - ECM)
a.

Disconnect the B78 wiring harness connector.


b.

Disconnect the B77 ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B78-6 (SL) - B77-3 (SL) Always Below 1 Ω
B78-6 (SL) or B77-3 (SL) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
a.
C226545
0.594,0.76 0.938,1 0.344,0.24 2.083,1.5 1.885,0.792 true 0.354,0.219 0.667,0.417 0.313,0.198 10 *a 2.031,1.552 2.646,1.75 0.615,0.198 10 SL 0.708,0.792 1.063,0.99 0.354,0.198 10 A
*a Component without harness connected
(Transmission Wire)


Remove the wiring harness connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-6 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

4.INSPECT SHIFT SOLENOID VALVE SL
4.INSPECT SHIFT SOLENOID VALVE SL
a.
C206832
0.104,0.104 0.417,0.302 0.313,0.198 10 *1 2.531,1.615 2.781,1.813 0.25,0.198 10 (+) 3.125,1.604 3.333,1.802 0.208,0.198 10 (-)
*1 Shift Solenoid Valve SL


Remove shift solenoid valve SL.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SL connector

·

Battery negative (-) → Shift solenoid valve SL body


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK