Home › Engine / Hybrid System › 2AR-FE EMISSION CONTROL › PURGE VALVE
RM30B0U _51 Engine / Hybrid System _009089 2AR-FE EMISSION CONTROL _0049672 PURGE VALVE A

2AR-FE EMISSION CONTROL  PURGE VALVE  INSTALLATION  


PROCEDURE

Hide 1.INSTALL PURGE VSV

a.

Install the purge VSV to the air cleaner hose with the claw.


b.

Connect the fuel vapor feed hose and No. 2 fuel vapor feed hose to the purge VSV, and slide the 2 clamps to secure it.


c.

Attach the wire harness clamp.


d.

Connect the purge VSV connector.