Home › Engine / Hybrid System › 2AR-FE EMISSION CONTROL › PURGE VALVE
RM30B0U _51 Engine / Hybrid System _009089 2AR-FE EMISSION CONTROL _0049672 PURGE VALVE G

2AR-FE EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 1.INSPECT PURGE VSV

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω
1 - VSV body ground Always 10 MΩ or higher
2 - VSV body ground 10 MΩ or higher


If the result is not as specified, replace the purge VSV.


b.

Check the operation of the purge VSV.

i.
A293414
0.802,1.604 0.802,1.135 true 1.208,1.917 1.375,1.917 1.375,1.917 1.563,1.229 true 1.042,1.844 1.198,2.01 0.156,0.167 10 *1 0.729,1.625 0.917,1.781 0.188,0.156 10 *2
*1 Port E
*2 Port F
V100135

Air


Check that air does not flow from port F when air is applied to port E.


ii.
A293415
0.76,1.125 0.76,0.844 true 1.115,1.365 1.115,1.167 1.115,1.167 1.292,0.885 true 1.594,0.74 1.885,0.406 1.885,0.406 2.135,0.406 true 1.583,0.833 1.781,1.031 true 0.969,1.604 1.125,1.771 0.156,0.167 10 *1 0.677,1.146 0.833,1.313 0.156,0.167 10 *2 1.802,1.01 1.948,1.167 0.146,0.156 10 *3 2.167,0.323 2.344,0.49 0.177,0.167 10 *4
*1 Port E
*2 Port F
*3 Terminal 1
*4 Terminal 2
V100135

Air


Apply battery voltage to the connector, and check the VSV operation.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Air flows from port E to port F


If the result is not as specified, replace the purge VSV.